Legrand NP800 Series User Manual Page 1

Browse online or download User Manual for Hardware Legrand NP800 Series. Legrand NP800 Series User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
NP800 Series
Jumbo Tele-Power
®
Pole
INSTALLATION INSTRUCTIONS
Installation Instruction No.: INS00006R1 – Updated April 2005
Wiremold Electrical Systems conform to and should be
installed and properly grounded in compliance with
requirements of the current National Electrical Code, Canadian
Electrical Code or codes administered by local authorities.
All electrical products may represent possible shock or fire
hazard if improperly installed or used. Wiremold electrical
products are UL Listed to U.S. and Canadian safety
standards, made for interior use only, and should be installed
in conformance with current local and/or the National
Electrical Code.
NP800 Series Tele-Power Poles are provided standard with an anodized aluminum finish or may be painted any number of color
selected from a full array of powder coat finishes. Standard poles have two channels of different depths. These channels may be
divided at various locations by snap-in dividers to form additional channels. All channels may enclose either power or
communication wiring. Wire fill capacities are outlined below, followed by illustrations of standard pole hardware, and instructions
for a typical installation (over). Poles may be supplied with box ends of various sizes. Walkerflex™ Manufactured Wiring System
Connectors or with 10' [3.04m] cord ends (cUL only).
CABLE TYPE UNSHIELDED TWISTED PAIR SHIELDED TWISTED PAIR COAX TWINAX
DESCRIPTION CAT 3 CAT3 CAT5e CAT5 CAT6 TYPE 1 TYPE 2 TYPE 9 RG58/U RG59/U RG62 RG6U 100 OHM
4 PAIR 25 PAIR 4 PAIR 25 PAIR 4 PAIR 22 AWG 22 AWG 22 AWG 20 AWG 22 AWG 22 AWG 18 AWG
NOMINAL O.D. (In.) 0.19 0.36 0.21 0.337 0.25 0.39 0.465 0.275 0.195 0.242 0.242 0.27 0.24
2.4 25.0 7.0 20.0 8.0 14.0 6.0 4.0 12.0 24.0 15.0 15.0 12.0 15.0
2.8 29.0 8.0 24.0 9.0 17.0 7.0 4.0 14.0 28.0 18.0 18.0 14.0 18.0
3.2 33.0 9.0 27.0 10.0 19.0 8.0 5.0 16.0 32.0 20.0 20.0 16.0 21.0
4.2 44.0 12.0 36.0 14.0 25.0 10.0 7.0 21.0 42.0 27.0 27.0 22.0 27.0
4.3 45.0 12.0 37.0 14.0 26.0 10.0 7.0 21.0 43.0 28.0 28.0 22.0 28.0
4.8 50.0 14.0 41.0 16.0 29.0 12.0 8.0 24.0 48.0 31.0 31.0 25.0 31.0
5 52.0 14.0 43.0 16.0 30.0 12.0 8.0 25.0 50.0 32.0 32.0 26.0 33.0
5.2 55.0 15.0 45.0 17.0 31.0 13.0 9.0 26.0 52.0 33.0 33.0 27.0 34.0
5.8 61.0 17.0 50.0 19.0 35.0 14.0 10.0 29.0 58.0 37.0 37.0 30.0 38.0
6.2 65.0 18.0 53.0 20.0 37.0 15.0 10.0 31.0 62.0 40.0 40.0 32.0 41.0
7 74.0 20.0 60.0 23.0 42.0 17.0 12.0 35.0 70.0 45.0 45.0 36.0 46.0
7.7 81.0 22.0 66.0 25.0 47.0 19.0 13.0 38.0 77.0 50.0 50.0 40.0 51.0
8 84.0 23.0 69.0 26.0 48.0 20.0 14.0 40.0 80.0 52.0 52.0 41.0 52.0
12 126.0 35.0 103.0 40.0 73.0 30.0 21.0 60.0 120.0 78.0 78.0 62.0 79.0
DATA/COMMUNICATION: MAXIMUM WIRE FILLS FOR UL AND cUL LISTED TELE-POWER POLES
CAPACITY OF CROSS SECTION (In
2
)
SNAP-IN DIVIDERS AREAS OF CROSS SECTIONS
Large Compartment
Small Compartment
5"
[127mm]
2 13/16"
[71mm]
12 sq. in.
[7742mm
2
]
1 5/8"
[41mm]
4.3" sq. in.
[2774mm
2
]
7.7 sq. in.
[4698mm
2
]
2 3/16"
[71mm]
5.8" sq. in.
[3742mm
2
]
6.2 sq. in.
[4000mm
2
]
3 1/8"
[79mm]
5" sq. in.
[3226mm
2
]
7 sq. in.
[4516mm
2
]
1 5/8"
[41mm]
3.4" sq. in.
[2194mm
2
]
4.3 sq. in.
[2774mm
2
]
5"
[127mm]
1 15/16"
[49mm]
8 sq. in.
[5161mm
2
]
1 5/8"
[41mm]
2.8" sq. in.
[1806mm
2
]
5.2 sq. in.
[3355mm
2
]
2 3/16"
[71mm]
3.8" sq. in.
[2452mm
2
]
4.2 sq. in.
[2710mm
2
]
3 1/8"
[79mm]
3.2" sq. in.
[2065mm
2
]
4.8 sq. in.
[3097mm
2
]
1 5/8"
[41mm]
2.4" sq. in.
[1548mm
2
]
2.8 sq. in.
[1806mm
2
]
NOTE: Capacity range is calculated at 30% of raceway areas as stated in the Commercial Buildings Standard for Telecommunication Pathways
and Spaces, EIA/TIA-569.
These are the approximate diameter and cross-sectional areas for typical cables in each category. Check with the cable manufacturer for
more accurate dimensions.
Page view 0
1 2

Summary of Contents

Page 1 - NP800 Series

NP800 Series Jumbo Tele-Power®PoleINSTALLATION INSTRUCTIONSInstallation Instruction No.: INS00006R1 – Updated April 2005Wiremold Electrical Systems

Page 2 - WIRING OPTIONS

Wiremold / LegrandU.S. and International: 60 Woodlawn Street • West Hartford, CT 061101-800-621-0049 • FAX 860-232-2062 • Outside U.S. 860-233-6

Comments to this Manuals