Conventional UPS - Single phase On-line double conversion VFI
Cat. Nos. 3 100 50 3 100 51 3 100 52 3 100 53 3 100 56 3 100 54 3 100 57 3 100 58 3 100 59
General characteristics
Nominal power (VA) 1000 2000 3000 4500 6000 10000 10000
Active power (W) 800 1600 2400 4050 5400 9000 9000
Technology On‑line double conversion VFI‑SS‑111
Waveform Sinusoidal
Architecture Convertible tower and 19" rack
Input characteristics
Input voltage 230 V 380V 3F+N
Input frequency 50‑60 Hz ± 5% autosensing
Input voltage range 160 V ‑ 288 V full load 277V ‑ 485V
THD of input current
3%
Input power factor
0.99
Compatibility with gensets
Configurable for synchronism between the input and output frequencies, even for the highest frequency ranges,
±14%
Output characteristics
Output voltage 230 V ± 1%
Output frequency (nominal) 50/60 Hz (configurable via LCD panel) +/‑ 0.1%
Peak factor 1:3
THD of output voltage
3% with linear load
Output voltage tolerance ± 1%
Bypass
Automatic bypass and optional exter
nal manual bypass
Batteries
Backup time extension Yes
Number of batteries 3 6 6 20 20
Battery range type/voltage 12 V 7.2 Ah 12 V 7.2 Ah 12 V 9 Ah 12 V 5 Ah 12 V 5 Ah
Backup time (min) 10 10 8 6 4
Communication and management
Screen and signalling Four buttons and four LEDs for real‑time control of the status and the main parameters of the UPS
Communication ports RS232 and USB serial ports RS232 serial ports
Remote control Available
Connector for network interface SNMP
Back feed protection yes
Emergency power off (EPO) yes
Mechanical characteristics
Dimensions (H x W x D) (mm)
440x88 (2U)
x405
440x88 (2U)
x650
440x88 (2U)
x650
440x176
(4U) x680
440x88 (2U)
x680
440x176
(4U) x680
440x88 (2U)
x680
440x132 (3U)
x680
Net weight (kg) 16 29.5 30 52 25* 52 25* 26*
Dimensions of battery cabinet
H x W x D (mm)
440x176
(4U) x405
440x88 (2U)
x650
440x88 (2U)
x650
440x132
(3U) x680
440x132
(3U) x680
440x132 (3U)
x680
Ambient conditions
Operating temperature (°C) 0 ÷ 4C
Protection index IP 21
Relative humidity (%) 20 to 80%
Noise at 1 m (dBA)
50
Heat dissipation (BTU/h) 490 654 818 982 1310 1636
Certifications
Reference product standards EN 62040‑1, EN 620402, EN 62040‑3
* Weight without batteries
NOTE: The backup times, expressed in minutes, are measured under optimum operating conditions.
Page view 0
1 2

Summary of Contents

Page 1 - Daker Dk

Daker DkConventional UPS - Single phase On-line double conversion VFICat. Nos. 3 100 50 3 100 51 3 100 52 3 100 53 3 100 56 3 100 54 3 100 57 3 100 58

Page 2

WWW.UPS.LEGRAND.COMDaker DkLong backup time table1000 VA 2 cabinetsW 2U + 4U3000 VA 3 cabinetsW 2U +2 U + 2U6000 VA 2 cabinetsW 2U + 3U 10000 VA 2 cab

Comments to this Manuals

No comments