Wiremold electrical systems conform to and should be properly
grounded in compliance with requirements of the current National
Electrical Code or codes administered by local authorities.
All electrical products may present a possible shock or fire
hazard if improperly installed or used. Wiremold electrical products may
bear the mark as UL Listed and/or Classified and should
be installed in conformance with current local and/or the National
Electrical Code.
Products Covered: 6ATCFF, 6STC, 6CFFTC, 15FFHA, 152CHA, CE6ATCFF
CAUTION DO NOT operate tile stripper, cleaning, or resurfacing equipment over top of covers. This may result in
damage to the surface finish of the product.
Suitable for use in air handling spaces in accordance with Sec. 300-22 (C) of the National Electrical Code.
Evolution
Series
6" Furniture Feed Poke-Thru Devices
I N S T A L L A T I O N I N S T R U C T I O N S
Installation Instruction No.: 1 007 155 R2 Updated May 2010
24" [610mm] Min
Center – Center
7 1/4"
[166mm]
CAUTION: Be certain to locate hole at least 6" [152mm] from any wall or
pillar to leave enough room for Poke-Thru cover assembly.
IMPORTANT: Please read all instructions
before beginning.
CAUTION: Minimum spacing of 2ft on center and not more than
one device per each 65 square feet of floor area in
each span.
Step 2 Remove 7 1/4" dia. [166mm] section from
carpet or tile. Use template provided.
Step 1 Layout and locate position of hole(s).
FLOOR PREPARATIONS
Covered Floors 6" [152mm] 6 1/8" [156mm]
(Carpet, Tile or
Wood)
Bare Concrete 6 1/16" [154mm] 6 1/8" [156mm]
or Terrazzo
FLOOR CORE CORE
TYPE SIZE (Min.) SIZE (Max.)
Step 3 Create core hole according to the
dimensions provided in the chart.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Evolution

1Wiremold electrical systems conform to and should be properly grounded in compliance with requirements of the current NationalElectric

Page 2

2Step 2 Remove cover plates byremoving (5) 8-32 screws.Step 3 Remove 3/4" plug from smallcover plate by rotating counter-clockwise using a large

Page 3 - Step 7 Installation complete

3CAUTION: Cover must be removed to rotate Poke Thru once it has been installed in the floor.Step 6 Orient Poke Thru so that the three channels span a

Page 4 - Device openings must

4Device openings mustspan across deckCAUTION: Cover must be removed to rotate Poke Thru once it has been installed in the floor.Step 1 Orient Stem As

Page 5

5Step 2 Remove Poke Thru from floor by bendingtabs inward and pulling unit up.Step 1 Remove cover assembly from Poke Thru by removing (2) 8-32 screws

Page 6

Evolution Series Poke-Thru Devices are UL Listed and Classified to U.S. and Canadian safety standards to thefollowing conditions:The 6STC Poke-Thru St

Page 8 - Carpet Cutout Template

WIREMOLDU.S. and International: 60 Woodlawn Street • West Hartford, CT 061101-800-621-0049 • FAX 860-232-2062 • Outside U.S.: 860-233-6251 Canad

Comments to this Manuals

No comments