INSTRUCTION/INSTALLATION SHEET
Phone/Data 6 Port Module
IS-0340 REV. A
©Copyright 2006 by On-Q/Legrand All Rights Reserved.
1. Introduction
This Installation Sheet covers the Phone/Data 6 Port Module (P/N CO1000) normally housed in an On-Q
enclosure (see Figure 1), which helps to maximize the efficiency of each Cat 5e cable run by combining voice
and data over each Cat 5e (see the typical associated Phone/Data Wall Outlet in Figure 2).
2. Description
The Phone/Data 6 Port Module is provided with a Single Bay Module Mounting Bracket (P/N 364890-01) that
allows it to be installed in any On-Q style enclosure. The Phone/Data 6 Port Module includes a “PHONE IN” RJ-
45 jack for voice support of up to two incoming phone lines and six “DATA IN” RJ-45 jacks used for Ethernet data
support which is then combined with voice support onto the six “OUT TO ROOM” RJ-45 jacks. The “PHONE
CASCADE OUT” RJ-45 jack provides pass-through of all four incoming phone lines to any other modules in the
enclosure.
3. Installation
Although installation of the Phone/Data 6 Port Module may be performed as part of new construction, using the
traditional “rough-in” and “trim-out” steps, installation is most likely to occur as part of a retrofit procedure where
the customer’s desire is to expand capability of a single existing structured wiring cable.
A. Either run a new Cat 5e cable from the enclosure where the On-Q Phone/Data 6 Port Module will be installed to
a single gang box or mud ring at each location where a Phone/Data Wall Outlet Strap will be installed, or simply
remove the wall plate and disconnect an existing Cat 5e cable from an existing telephone or data RJ45 jack at
the desired location.
NOTE: See IS-0341 for installation instructions related to the Phone/Data Wall Outlet Straps.
NOTE: If a distributed video capability is desired at the new Phone/Data Wall Outlet Strap location, also run
a coax cable from the distribution device in the enclosure to the single gang box or mud ring for the strap.
Figure 1