Legrand EFB6S-FC Series User Manual

Browse online or download User Manual for Hardware Legrand EFB6S-FC Series. Legrand EFB6S-FC Series User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Wiremold
®
Evolution
Series Fire Classified Floor Boxes
Série Evolution
Boîtes de sol ignifuges
Cajas de pisos de la Serie Evolution
a prueba
de incendios


Country of Origin: Made in USA • Fabriqué en USA • Hecho en USA

Please read all instructions before
beginning installation
Legrand electrical systems conform to and
should be properly grounded in compliance with
requirements of the current National Electrical
Code or codes administered by local authorities.
All electrical products may present a possible
shock or re hazard if improperly installed or used.
Legrand electrical products may bear the mark of
a Nationally Recognized Testing Laboratory and
should be installed in conformance with current
local and/or the National Electrical Code.

VEUILLEZ LIRE L'ENSEMBLE
DES INSTRUCTIONS AVANT DE
COMMENCER L'INSTALLATION.
Les systèmes électriques Legrand sont
conformes au Code National de l'électricité
(National Electrical Code) ou aux codes
locaux en vigueur et doivent être mis à la terre
conformément à ces codes.
Tous les produits électriques peuvent présenter
un risque d'électrocution ou d'incendie s'ils ne
sont pas installés ou utilisés correctement. Les
produits électriques Legrand peuvent porter la
marque d'un laboratoire reconnu et doivent être
installés conformément au Code national de
l'électricité et/ou aux codes locaux en vigueur.

Lea todas las instrucciones antes
de comenzar la instalación.
Los sistemas eléctricos Legrand cumplen con los
requisitos del Código Eléctrico Nacional (National
Electrical Code, NEC) actual o con los códigos
impuestos por las autoridades locales y deben
conectarse a tierra consecuentemente.
Todos los productos eléctricos pueden presentar
un riesgo de descarga o incendio si se los instala o
utiliza incorrectamente. Los productos eléctricos
Legrand pueden llevar la marca de un laboratorio
de pruebas reconocido a nivel nacional y se deben
instalar conforme al código local en vigencia o al
Código Eléctrico Nacional.
No: 1010388R3 – 5/14 Installation Instructions • Notice d’Installation• Instrucciones de Instalación









Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Wiremold

Wiremold®Evolution™ Series Fire Classified Floor Boxes Série Evolution™ Boîtes de sol ignifuges Cajas de pisos de la Serie Evolution™ a prueba de incen

Page 2

Type EFB6S-FC, EFB8S-FC, and EFB10S-FC preset electrical inserts

Page 3



Page 4

No: © Copyright 2014 Legrand All Rights Reserved.© Copyright 2014 Tous droits réservés Legrand.© Copyright 2014 Legrand Todos los derec

Page 5

Cut opening into decking surface. Ensure that opening dimensions are approximately 17 1/2" x 22 3/16" [445mm x 584mm] as shown below.Décou

Page 6

Hammer over the screw tabs as shown to steel decking. Secure pan to decking surface with screws or by seam welding.Donnez un coup de marteau sur les

Page 7

TabLanguettePestañaA. Retirez la visA. Quitar tornilloB. Slide out tabB. Faites glisser la languetteB. Deslizar la pestañaC. Remove ta

Page 8

 MINIMUM THICKNESS FOR FIRE RESISTANCE RATING CEMENT TYPE     Normal Weight 3 1/2" [89mm] 4 5/16" [1

Page 9

Pour concrete into pan. Prior to pour minimize concrete drop through by sealing the pan to decking seams with tape or other methods. Fill pan with c

Page 10

If the nished oor is to be terrazzo, remove the protective cover from the box, and install the concrete/terrazzo trim ring kit. See instruction sh

Page 11

88 Accepts only EFB10 Series Faceplates Accepts standard size device plates (2 3/4" x 4 1/2" [70mm x 114mm])

Page 12 - No: 

Formed wire retainers are mounted to the inside of the box to help route wires and cables exiting the box. Retainers can be removed by loosening the

Comments to this Manuals

No comments