DS4000 Obstacle Avoidance
& Offset Fittings
INSTALLATION INSTRUCTIONS
Installation Instruction No.: 43266 – January 2006
Wiremold / Legrand Electrical Systems conform to and should be
installed and properly grounded in compliance with requirements
of the current National Electrical Code, Canadian Electrical
Code, or codes administered by local authorities.
All electrical products may represent possible shock or fire
hazard if improperly installed or used. Wiremold electrical
products are UL listed to U.S. and Canadian safety
standards, made for interior use only, and should be installed
in conformance with current local and/or the National
Electrical Code.
j
DS4075 INSTALLATION: To jump over small Conduits or Raceways:
Products Covered: DS4075, DS4075A
Existing Obstruction
8" [203mm]
Minimum Spacing
12" [305mm]
Maximum Spacing
DS4000B Raceway Base
DS4000B Raceway Base
Step 2. Install Transition Couplings, tighten set screws to secure.
Step 3. Install Internal Shroud on each side.
Step 1. Install DS4000B on either side of the obstacle. The DS4075 Obstacle Avoidance Fitting can transition over 1/2" and 3/4"
trade size conduit, water pipe, Wiremold 500 Series, 700 Series, 2100 Series, 2000 Series, and 2400 Series Raceways.
For more information, visit www.wiremold.com/ds4000.
Step 4. Install DS4000C Raceway Covers. Step 5. Remove appropriate twistout and secure cover. Push on
until it snaps in place
NOTE: To remove Cover or install a Tamper Resistance Kit, refer to page 6 of this instruction sheet.
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - & Offset Fittings

DS4000 Obstacle Avoidance& Offset FittingsINSTALLATION INSTRUCTIONSInstallation Instruction No.: 43266 – January 2006Wiremold / Legrand Electric

Page 2

2To use the DS4075 as a transition to Wiremold 500 Series or 700 Series Raceway:Step 1. Install 500/700 Adapter into the opening with suppliedscrews.

Page 3

3To use the DS4075 as a transition to Wiremold 2400 or 2400BD Series Raceway:Step 1. Install DS4075 as before. Install 2400 Adapter in onechannel for

Page 4

4DS4075A OFFSET FITTING INSTALLATION:Step 1. Measure the offset.Step 3. Mount to Wall with #8 minimum Fasteners. TightenSet Screws as Shown.Step 2. Tr

Page 5

5Step 5. Measure Cover distance from top of Divider.Step 7. Snap on Cover. Step 8. Install Elbow Cover and Inside Corner Trim.MeasureStep 6. Trim Cove

Page 6

6Cover Removal w/650RTFITTING COVER REMOVAL – Fitting Cover can be removed using two methods:Cover Removal w/ScrewdriverStep 1. Locate Dimple on Fitti

Page 7

7NOTES

Page 8

Wiremold / LegrandU.S. and International: 60 Woodlawn Street • West Hartford, CT 061101-800-621-0049 • FAX 860-232-2062 • Outside U.S. 860-233-6

Comments to this Manuals